Fire Detection in Electrical Switchgear Installations

Catastrophic consequences

Fires in high and low tension switchgear installations, transformer stations and substations hold great dangers. Apart from the in part catastrophic consequences of a power failure, highly toxic and ecologically harmful gases and waste products are caused by fires in transformers and insulating materials.

Fires can break out in various ways: Overheating of parts of an installation, electric arcing during switching procedures and leak currents are possible fire risks due to operating. A further risk is provided by human beings themselves, e.g. welding works and cigarettes,etc. thrown away carelessly are the repeated cause of fire.

topo

Unpractical point detectors

The optical smoke detector is really the right detection principle in the field of electrical fire risks. However, application problems arise here for practical reasons: Because of safety clearances, no weak current systems may be installed in the high-voltage sector. So fire detectors cannot be mounted directly above the facilities to be monitored. For safety reasons, no scaffolding and ladders may be used for the periodical checks on functioning. Detectors have therefore to be mounted on a raisable base so that it will not be necessary to switch off the high voltage for functional checks. In the switchgear installation sector, massive EMV interference is to be expected through electrical arcing. As a result, fire detectors may be impaired in their operation.

topo

With the ASD aspiration smoke detection system

The ASD smoke suction system is excellently suited for fire detection in electrical switchgear installations, substations and transformer stations:
– The suction tubes are made of nonconductive plastic (PVC or halogenfree PP) and can therefore be fitted without problems through the highvoltage area.
– The evaluation unit is easily reached as it can be mounted in the safe area, if possible even outside of the highvoltage room. Functional checks and maintenance works can be carried out simply and thus for a reasonable cost, and without any danger. It is not necessary to switch off the high voltage for this.
– The aspiration smoke detection systems have excellent detection properties which, depending on the version, give an early warning system with multistage detection. The Securiton installation guidelines for aspiration smoke detection systems apply for the arrangement of the suction tubes.


Raisable conventional detector (view)


Complete monitoring with ASD aspiration smoke detection system (view)


Possibilities for arranging the suction tubes (view)

topo

Exemplos de aplicações para o sistema de aspiração de fumaça ASD:

Installation monitoring in EDP systems and control cabinets

Protection of hollow floors and hollow ceilings

Supervision of prison cells and isolation wards in clinics

Fire detection in high-storage warehouses

Invisible fire detection for the protection of cultural goods

Fire detection in electrical switchgear installations

Fire detection in cold-storage warehouses

Fire protection in unheated rooms, e. g. roof frameworks

Fire protection in high voltage and EMV laboratories